Projet

Général

Profil

AirOS » Historique » Version 13

« Précédent - Version 13/63 (diff) - Suivant » - Version actuelle
Laurent GUERBY, 19/05/2012 23:30


AirOS

http://www.ubnt.com/wiki/RF_Compliance

For example, if you select 5805 MHz (40 MHz channel) and Below, the radio will use (5775 to 5795 MHz) + (5795 to 5815 MHz),
but if you select 5805 MHz (40 MHz channel) and Above, the radio will use (5795 to 5815 MHz) + (5815 to 5835 MHz).

v5.3.5

http://wiki.ubnt.com/AirOS_5.3

Channel width 5/10/20/40

TX power min max dBm
Loco 4 23
NS 8 27
NB 4 23
Rocket -4 27

LocoM2 5/10/20/40 dBm 5-23

v5.5

http://www.ubnt.com/download#doc
http://www.ubnt.com/downloads/guides/airOS/airOS_UG_V55_3-20-12.pdf

Country Compliance Mode Frequency 4920 Mhz a 6100 MHz
Channel width 3/5/8/10/20/25/30/40

TX power min max dBm
Loco 4 23
NS -4 27
NB -8 23
Rocket -4 27

LocoM2 3/5/8/10/20/25/30/40 dBm 5-23 Freq 2312 a 2732 MHz

IPv6 supported in command line ping6 fe80::xxx%br0 works

AirView test

Lab on table same room compliance mode 5.5
- one NSM5 AP WDS
- one LocoM5 STA WDS 1 meter from the NSM5
- one NBM5 head (without dish) right in between Loco and NS running AirView

Steps for each graph
  1. associate NS and Loco with new frequency and width
  2. clear airview
  3. launch 300 second iperf client between netbook behind NSM5 to iperf server on locoM5
  4. after iperf is done save airview screenshot
  5. go back to step 1

First batch testing narrow channels 5240 with 5200-5300 airview:

  • 3 MHz
  • 5 MHz
  • 8 MHz
  • 10 MHz
  • 20 MHz

Second batch testing large channels 5300 with 5200-5400 airview:

  • no emission to verify noise
  • 10 MHz
  • 20 MHz
  • 30 MHz
  • 40 MHz